产品简要
公司名称 :
BioLegend
其他品牌 :
Babco, Signet, Sternberger Monoclonals, Senetek, Covance
产品类型 :
ELISA/assay
产品名称 :
Veri-Cells™ PBMC
目录 :
425004
规格 :
50试验
价格 :
275美元
更多信息或购买 :
文章摘录数: 3
参考文献
Haredy A, Takei M, Iwamoto S, Ohno M, Kosaka M, Hirota K, et al. Quantification of a cell-mediated immune response against varicella zoster virus by assessing responder CD4high memory cell proliferation in activated whole blood cultures. Vaccine. 2019;37:5225-5232 pubmed 出版商
Labuhn M, Perkins K, Matzk S, Varghese L, Garnett C, Papaemmanuil E, et al. Mechanisms of Progression of Myeloid Preleukemia to Transformed Myeloid Leukemia in Children with Down Syndrome. Cancer Cell. 2019;36:123-138.e10 pubmed 出版商
Sun Y, Yang K, Bridal T, Ehrhardt A. Robust Ki67 detection in human blood by flow cytometry for clinical studies. Bioanalysis. 2016;8:2399-2413 pubmed
产品信息
Apps. Abbrev. :
流式细胞仪, 流式细胞仪细胞内染色
目录 :
425004
产品 :
Veri-Cells™ PBMC
其他名称 :
Control cells
规格 :
50试验
价格(美元) :
275美元
共轭标签/标签/标记 :
应用注释 :
The Veri-Cells PBMC Kit can be used as positive controls for surface immunofluorescent staining and multi-color flow cytometry assays using the BioLegend surface staining protocol. It can also be used for the detection of intracellular molecules such as Granzyme B, Perforin, Foxp3 and Helios using BioLegend s Fixation Buffer and Intracellular Staining Permeabilization Wash Buffer (10X) or the True Nuclear Transcription Factor Buffer Set. For best results, Cell Staining Buffer is recommended for any washing steps. Product performance specifications are based on testing with BioLegend reagents and protocols. Deviations from the use of these reagents and procedures have not been assessed and may affect performance. Please use our CoA Look-Up Tool to find the expected lot-specific frequencies of certain cell populations included within each lot of Veri-Cells PBMC. The antibodies used for testing were the following: CD56 PE (clone 5.1H11), CD16 PE (clone 3G8), CD19 APC (clone HIB19), CD3 FITC (clone UCHT1), CD4 PE/Cy7 (clone RPA-T4), CD8 APC/Cy7 (clone RPA-T8). Percent positive is based on gates set on unstained cells. The Certificate of Analysis specific values are provided only as a reference. Variability in antibodies used, instruments, staining conditions and other factors may influence end-user values. It is recommended that individual laboratories establish its own control values and ranges for each parameter based on laboratory specific conditions and protocols.
更多信息或购买 :
公司信息
BioLegend
8999 BioLegend Way
San Diego, CA 92121
customerserv@biolegend.com
https://www.biolegend.com
1-858-455-9588
公司总部: 美国
Biolegend公司为生物医学研究提供顶级的抗体及试剂产品,旨在加速生命科学领域的研发工作。