产品简要
公司名称 :
MyBioSource
产品类型 :
ELISA/assay
产品名称 :
3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ELISA Kit
目录 :
MBS2021017
规格 :
48-Strip-Wells
价格 :
605美元
更多信息或购买 :
产品信息
目录号 :
MBS2021017
产品类型 :
酶联免疫吸附试剂盒
产品全称 :
3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ELISA Kit
产品简称 :
3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR)
产品名称同义词 :
HMG CoA还原酶;羟甲基戊二酰辅酶A还原酶
其他名称 :
3-hydroxy-3-methylglutaryl Coenzyme A reductase; 3-hydroxy-3-methylglutaryl coenzyme A reductase; 3-hydroxy-3-methylglutaryl-CoA reductase
产品基因名称 :
HMGCR
其他基因名称 :
MPET_RS02765;Mpet_0546;HMG CoA还原酶
UniProt数据库进入名 :
E1RHL1_METP4
反应物种 :
大鼠
序列长度 :
401
特异性 :
This assay has high sensitivity and excellent specificity for detection of HMGCR. No significant cross-reactivity or interference between HMGCR and analogues was observed.
储存稳定性 :
For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 degree C upon receipt while the others should be at 4 degree C. For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal. The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
其它信息1 :
Samples: Rat tissue homogenates, cell lysates and other biological fluids. Assay Type: Sandwich. Detection Range: 0.312-20ng/mL. Sensitivity: 0.126ng/mL
其他信息2 :
Intra-assay Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level HMGCR were tested 20 times on one plate, respectively. Intra-Assay: CV<10%. Inter-assay Precision: Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level HMGCR were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Inter-Assay: CV<12%
产品描述 :
Intended Uses: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of HMGCR in rat tissue homogenates, cell lysates and other biological fluids. Principle of the Assay: The microtiter plate provided in this kit has been pre-coated with an antibody specific to HMGCR. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to HMGCR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain HMGCR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of HMGCR in the samples is then determined by comparing the O.D. of the samples to the standard curve.
NCBI GI登录号 :
307155940
NCBI登录号 :
ADN35320.1
NCBI分子量 :
42,107 Da
NCBI信号通路 :
Biosynthesis Of Secondary Metabolites Pathway (170166); Metabolic Pathways (170150); Terpenoid Backbone Biosynthesis Pathway (170146); Terpenoid Backbone Biosynthesis Pathway (408)
尺寸1 :
48-Strip-Wells
价格1 :
605美元
尺寸2 :
96-Strip-Wells
价格2 :
820
size3 :
5x96-Strip-Wells
价格3 :
3220
size4 :
10x96-Strip-Wells
price4 :
5795
更多信息或购买 :
公司信息
MyBioSource
P.O. Box 153308
San Diego, CA 92195-3308
sales@mybiosource.com
https://www.mybiosource.com
1-858-633-0165
公司总部: 美国
MyBioSource,LLC最初由三名热情澎湃的提供高品质试剂的科学家联合创立于温哥华,公司愿景是“生物研究试剂的源头”,现在位于圣地亚哥市。